Well, not without exporting the project database on 32 bit OS first.Unfortunately, as the story goes, Watcom doesnt provide a way to access the data in this database product on 64 bit Windows operating systems.If you have any comments, questions, or corrections, please dont hesitate to leave them by filling in the post a comment or question link below.
In 1999 Shawn launched his first website which was the pre-cursor to TheAutomationBlog.com which he launched in 2013. Today Shawn continues to publish and edit content for The Automation Blog while also teaching PLC, HMI, and SCADA courses at TheAutomationSchool.com. Latest posts by Shawn Tierney ( see all ) Get Ready For Your New Automation Career - April 12, 2021 PLCnext: The Next Generation of PLCs (P68) - April 2, 2021 Online Training with an Offline Option - March 31, 2021. ![]() We used another method than what you expalined here but when we tried to open the files on the panelview through Asset Center, we could not. Therefore if we ever need to make changes on the HMIs in the future we can not. Rockwell told us it cant be done, to either keep an old XP machine around or use virtual machine. The explanation being that once the file is converted to the 6.1 64 bit file it cant be used on the old 5.1 32 bit HMIs to make changes. Software Panelbuilder 1400E V5.15 Patch Windows 7 64 BitWill the procedure you described here allow us to make changes from windows 7 64 bit on the old HMIs or simply view the HMIs Thanks Shawn Mike. So, ViewStudio 8.0 can in fact make a version 3.2 MER file to run on an old legacy PVPlus. So a version 5.1.MER created with ViwStudio 6.1 (or higher) cant be opened in ViewStudio 5.1 again. Software Panelbuilder 1400E V5.15 Patch Code Have ItI would like to scan the bar code have it display on the HMI then scan again using the displayed code on the HMI then when we have a tote of parts complete the black hawk system will print the proper tote label.Do you think this is possible most of our PLCS are compact logix and HMIS are panel view plus. Im using the 7.00.00 (CPR9 SR6) FactoryTalk View Studio version on windows 7 64bit. Software Panelbuilder 1400E V5.15 Patch Software Installed OnI have factorytalk software installed on a windows 7 computer. All I have is the existing program file (.mer). Is it possible to make edits to the (.mer) file using the windows 7 computer and then load it back onto the HMI. ![]() Special thanks to our Sponsors, Advertisers, and Community Members who make it possible for us to continue our work. Other trademarks are property of their respective companies.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |